general data repeat accuracy < 0,001 mm activating force 50 cn mech. pre-run / overrun - / 1,5 mm approx. measurement type contact with medium direction of approach frontal electrical data dc voltage max. 15 vdc switch. current dc max. 2 ma ac voltage max. 24 vac switch. current ac max. 50 ma output circuit break function (nc) mechanical mechanical data activating pin zirconium oxide zro2 housing material brass nickel plated dimension 8 mm type rectangular housing length 20 mm connection types cable, 80 cm ambient conditions operating temperature -20 ... +75 c protection class ip 50 photo connection diagram + ? dimension drawing 1, 5 20 4 12 9 12 1 ? 4 8 2, 5 8/1/2014 my-com c50/80 my-com c50/80 my-com precision switches my-com precision switches www.baumer.com
|